Buyers searching for contactors from Yueqing often receive quotations that look comparable but describe different electrical duties. A model marked 25A may be suitable for one load and unsuitable for another because the figure can refer to AC-1, AC-3 or a specific application rating.

This guide explains how to build a contactor specification for a Yueqing supplier, compare quotations on the same basis and decide what to verify during a factory visit. It is a buying guide rather than a manufacturer ranking. For company profiles, see our Yueqing contactor manufacturer shortlist.

How this guide was prepared: Based on publicly available manufacturer documentation and product information reviewed on 22 October 2026. Ratings, accessories and certification scope vary by model and must be confirmed in the supplier’s current datasheet and order documentation. This guide is not electrical design advice or a substitute for local installation rules.

Start with an electrical brief, not an ampere rating

A contactor is an electrically operated switching device. It does not, by itself, provide complete motor overload and short-circuit protection. The buying brief should therefore describe the complete switching duty and the protective devices around it.

For a motor application, start with the motor nameplate and the installation design. Record the rated voltage, frequency, full-load current, motor output, starting method, expected starts per hour and the load driven by the motor. Then identify the utilization category, coil supply, required main poles, auxiliary contacts and whether a thermal overload relay or other protective arrangement will be used.

Brief field What to specify Why it changes the quotation
Application Motor starting, resistive heating, lighting, capacitor switching, reversing duty, DC switching or another defined load. Different loads produce different inrush, arc and operating conditions.
Utilization category AC-1, AC-3, AC-4 or the applicable category for the load and duty. A contactor’s current rating depends on the category and intended switching duty.
System voltage and frequency Rated operational voltage, number of phases and supply frequency. The same model code may have different published ratings at different voltages.
Motor or load current Full-load current from the nameplate, plus starting current and expected operating cycle. Motor power alone is not enough to select or compare a contactor.
Coil supply Coil voltage, AC or DC, frequency and control-circuit source. A contactor with the right main rating but the wrong coil cannot be commissioned as supplied.
Main and auxiliary contacts Number of poles, normally open/normally closed arrangement, auxiliary contacts and interlocking. Contact configuration and accessories affect model choice, wiring and panel space.
Protection and coordination Thermal overload relay, short-circuit protective device and required coordination information. The contactor is part of a starter assembly, not a complete motor-protection solution.
Environment and installation Ambient temperature, enclosure, altitude, mounting direction, duty cycle and terminal requirements. Derating, clearance and accessory compatibility can change with the installation.
Destination and quantities Destination market, required standards and documents, annual or trial-order quantity, OEM requirements. Documentation, marking, packaging and approval requirements vary by market and order.

Read AC-1, AC-3 and AC-4 correctly

Utilization categories describe how a contactor is used. In simple terms, AC-1 covers non-inductive or slightly inductive loads, while AC-3 covers squirrel-cage motors switched during running. AC-4 covers more severe motor duty, including plugging, reversing and inching. The exact definitions and test requirements should be read in the applicable product standard and the manufacturer’s datasheet.

Do not take the largest current printed on a catalogue page and assume it applies to your motor. A contactor may have a relatively high AC-1 rating for resistive loads and a lower AC-3 rating for motor switching. Frequent starting, reversing or inching can require an AC-4 rating or a larger frame, and the electrical and mechanical life figures should be considered separately.

For a motor starter, the contactor, overload relay and short-circuit protective device must be coordinated. Ask the supplier for the specific combination that its documentation supports, rather than selecting each item only by its individual current rating.

Match the coil to the control circuit

The coil is the contactor’s control input. Its voltage and frequency must match the control supply, and the available tolerance matters where the control voltage fluctuates. A 220/230V AC coil is not interchangeable with a 24V DC coil, even if the main contacts have the same rating.

  • Control source: state whether the coil is supplied from the same system voltage, a separate control transformer, a PLC output or a DC supply.
  • Voltage and frequency: specify the nominal coil voltage and AC frequency, or DC voltage, including the acceptable operating range.
  • Pick-up and drop-out behaviour: confirm the published coil operating limits and whether the control circuit includes a relay or interface where required.
  • Environment: ask whether the coil and contactor are suitable for the ambient temperature and enclosure conditions at the installation.

Specify contacts and accessories as part of the model

Two suppliers may quote the same contactor family but different contact arrangements. Put the main poles, auxiliary contacts and accessories in the written brief. If reversing, star-delta starting or another assembled function is required, describe the complete arrangement and ask for the compatible accessories and wiring information.

Auxiliary contacts are not all electrically equivalent. Check the published contact rating and utilization category for the auxiliary circuit, especially when it switches a PLC input, interlock, indicator or another contactor coil. Confirm whether the auxiliary block is factory-fitted or supplied separately and whether the proposed combination has a clear catalogue reference.

Treat the contactor as part of a starter

A standard contactor provides controlled switching, not complete motor protection. A motor starter normally combines a contactor with an overload relay and may also include a short-circuit protective device, enclosure and control components. The exact arrangement depends on the installation design and applicable rules.

When requesting a quotation, ask for the contactor, overload relay and protective device as a coordinated set. Provide the motor full-load current, service factor where applicable, starting method, ambient conditions and expected duty. The overload relay setting range must cover the required current, and the supplier should identify the coordination document or table that applies to the proposed combination.

Do not accept a contactor quotation as evidence that the complete starter has been designed, tested or certified. Those are separate questions.

Compare quotations line by line

Ask every Yueqing supplier to quote the same brief and to mark any deviation rather than substituting a different model silently. A lower unit price can disappear once the missing coil, auxiliary block, overload relay, certificate or accessory is added.

Quotation item What to check
Manufacturer and legal entity The brand, contracting entity, production site and whether the supplier is the factory, an authorised distributor or a trading company.
Complete model reference The series, frame, coil code, main contact arrangement and auxiliary configuration, not only a generic series name.
Electrical ratings Utilization category, operational voltage, current, frequency, coil supply and any applicable derating.
Protective coordination The matching overload relay, short-circuit device and the manufacturer’s coordination information for the proposed set.
Included accessories Auxiliary contacts, interlock, mounting parts, coil suppressions and other items listed separately or included in the price.
Documents Current datasheet, dimensions, wiring diagram, declaration or certificate that names the exact model and destination-market scope.
Commercial terms MOQ, sample charge, packaging, lead time, Incoterms, warranty, spare parts and change-control arrangements.
Quality and traceability Batch identification, incoming inspection, production and final-test records that the factory is willing to discuss.

A documented Yueqing example: VIOX CJX2 range

VIOX Electric’s official AC-contactor page lists seven published CJX2 series examples, from the CJX2-0911 to the CJX2-9511, and directs buyers to separate pages for modular contactors and overload relays. Its product guidance says a contactor should be selected using motor data, system voltage, utilization category, operational current, duty and coordination requirements rather than motor power alone.

The same guidance states that a standard contactor performs switching, while motor overload and short-circuit protection require coordinated protective devices. That is a useful example of the questions a buyer should put to any Yueqing supplier, not a statement that one brand is suitable for every application.

Official sources: VIOX AC contactor range · VIOX overload and motor relays · Company and contact information.

What to verify before ordering

Once the shortlist is reduced, ask each supplier for the exact model-level documents. Check that the model, coil, contact arrangement, ratings and accessories in the quotation match the datasheet. If a certificate or declaration is important for market access, check that it names the exact product and scope rather than covering only a related series.

  • Sample inspection: compare the label, ratings, coil, terminals, contacts, accessories and dimensions with the approved data.
  • Performance evidence: ask what electrical and mechanical tests are performed on the proposed model and how test records relate to the production batch.
  • Change control: confirm how the supplier will notify you about changes to components, production location, marking or specifications before repeating an order.
  • Order documents: put the complete model reference, accessories, packaging, inspection criteria, documents and delivery terms in the purchase order.

Use a factory visit to test the answers

A factory visit is useful after the supplier has answered the technical and commercial questions. Ask to see the production area for the proposed contactor family and the processes that matter to the model, such as coil winding, moulding, contact assembly, calibration, electrical testing, marking and packing where applicable.

Bring the written specification and the proposed quotation. Compare what is being assembled, tested and recorded with what the supplier has offered. A visit can confirm observations and answers, but it is not a type test, product certification or guarantee of future production quality.

BottomRace coordinates electrical sourcing and purchasing in Yueqing. Pro: $0 separate service fee; procurement service costs are included in the product quotation. Basic: 5% of product value, with a minimum service fee of $100, for your existing Yueqing suppliers. Compare our Pro and Basic services. For on-site meetings, see our factory visit services. The quotation confirms the scope, inspections, payment terms and any additional costs.

Buyer questions

Can I choose a contactor by motor kW alone?

No. Use the motor nameplate current, supply voltage and frequency, utilization category, starting and operating duty, coil supply and protective coordination. Motor output is useful context, but it is not a complete selection input.

Is a larger contactor always better?

Not automatically. A larger frame may be unnecessary, may not fit the panel or may not match the intended accessories and protection. Select the model against the actual duty and the manufacturer’s published ratings rather than adding current arbitrarily.

Does the contactor include an overload relay?

Usually not unless the quotation says so. Confirm whether the price covers the contactor alone or a coordinated starter set with an overload relay and other specified components.

Can I use the same contactor for AC and DC loads?

Do not assume so. AC and DC circuits have different arc behaviour and the product must be rated for the intended load. A model intended for AC motor switching may not be suitable for a DC application.

What should I send to a Yueqing supplier?

Send the application, motor or load data, voltage and frequency, utilization category, required current, coil supply, contact arrangement, accessories, quantity, destination market and required documents. Ask the supplier to quote the complete model reference and list every deviation.

Need help comparing contactor quotations?

Email your motor data, utilization category, voltage, coil supply, contact arrangement, quantity and destination market. We can help you prepare a consistent brief and discuss local supplier support in Yueqing.

contact@bottomrace.com ↗

Enquire about Pro sourcing · Enquire about Basic supplier management.