Comparing motor starter manufacturers in Yueqing? CHINT, DELIXI, PEOPLE, TENGEN, Changan, Kripal, VIOX, Long Road, Winston and CHZIRI are ten companies to investigate. Their published ranges cover enclosed magnetic starters, direct-on-line (DOL) starters, star-delta starters, soft starters and components for starter assembly. The shortlist below identifies what each company actually publishes, so you can send the right suppliers a comparable enquiry.

Define the supply scope before comparing prices. A complete enclosed starter, an open contactor-plus-overload combination and a soft-starter unit require different accessories, wiring and protection. A contactor alone does not provide motor overload protection. Tell suppliers whether you want components, an assembled starter or a fully wired cabinet, then ask for the exact configuration and its supporting documents.

How this list was selected: Official product, contact and catalogue pages were reviewed on 23 October 2026. The order is a research shortlist, not a quality, price, certification, export or “best” ranking. Published product ranges and addresses support the initial comparison; they do not mean BottomRace has audited every listed factory. Confirm the legal entity, production site and evidence for the exact starter configuration before ordering.

Ten Yueqing motor starter manufacturers to compare

Start with the required starting method and delivery scope. The final column highlights the point to settle before requesting a price.

Manufacturer Published location Published starter focus Useful first question
CHINT Electrics CHINT Industrial Zone, North Baixiang, Yueqing Motor-starter range and NXC contactor / NXR overload-relay platform Is the quotation for an assembled starter or the specified NXC/NXR components?
DELIXI Electric DELIXI High-Tech Industrial Park, Liushi, Yueqing; English product site also lists Shanghai CDS2s enclosed electromagnetic starters Which CDS2s frame, overload range and coil-voltage code are included?
People Electrical Appliance Group Co., Ltd. No. 555 Liule Road, Liushi, Yueqing Magnetic starters and RDZR8-SP bypass soft starters Do you need a contactor-based magnetic starter or a bypass soft starter?
TENGEN Electric Sulv Industrial Zone, Liushi, Yueqing TGS51 enclosed DOL starters and TGS3 soft starters Which TGS51 configuration or TGS3 starting duty matches the motor?
Changan Group No. 288 Wei 17th Road, Yueqing Economic Development Zone CQ1 magnetic starters with contactor and thermal relay Which CQ1 contactor, thermal range and control arrangement are supplied?
Zhejiang Kripal Electric Co., Ltd. Zhongfang Intelligent Industrial Park, Beibaixiang, Yueqing; also Daqiao Industrial Zone UKQ and UKW magnetic-starter families Which UKQ or UKW model, enclosure and overload configuration are offered?
VIOX Electric East Innovation Zone, Wengyang Town, Yueqing CJX2 contactors and JR28 overload relays for starter assembly Does the quotation cover components, a wired combination or a complete enclosed starter?
Yueqing Long Road Electric Co., Ltd. No. 221 Wei 17 Road, Yueqing Economic Development Zone QCW1 / QCX2 starters, ADS7 / QCX3 star-delta starters and AJR3 soft starters Which starting method and complete model configuration are included?
Yueqing Winston Electric Co., Ltd. Liufeng Building, Liushi, Yueqing WSTRD-F3000 built-in-bypass motor soft starters Which F3000 current rating, duty and bypass arrangement are documented?
ZIRI Electrical Technology Co., Ltd. (CHZIRI) Building 2, Phase II, CHINT IoT Sense Industrial Park, Yueqing ZJR2 soft starters and motor-control panels Is the selected ZJR2 supplied with an internal bypass or an external bypass circuit?

Manufacturer profiles and sourcing questions

1. CHINT Electrics

Short name: CHINT
Published location: CHINT Industrial Zone, North Baixiang, Yueqing

CHINT's industrial-control range includes starters that combine contactors with overload relays. Its NXC contactor and NXR thermal overload relay pages also provide a starting point for buyers specifying a component-based motor-control panel. The useful distinction is the supply scope: an individual NXC contactor, an NXC/NXR combination and an enclosed starter are different purchases. Ask CHINT to identify the starter catalogue number or the exact component combination, rather than treating every industrial-control product as a complete starter. Confirm the production site for the offered model through the quotation and supporting documents.

Before requesting a quote: Provide the motor current, supply and control voltages, starting method and enclosure requirement. Request the matching contactor, overload setting range and trip class, wiring diagram, short-circuit protective device and coordination table. State whether push buttons, isolation, interlocks and panel assembly must be included.

Official sources: Industrial control and starters · NXC contactor · NXR overload relay · contact page.

2. DELIXI Electric

Short name: DELIXI
Published location: DELIXI High-Tech Industrial Park, Liushi, Yueqing; English product site also lists Shanghai

DELIXI publishes the CDS2s electromagnetic starter for direct starting and stopping of three-phase induction motors with overload protection. Its official catalogue lists 13, 32, 65 and 95 A housing frames, adjustable overload ranges and versions with or without push buttons. The catalogue separates AC-3 operating current, motor power at 380 V and control-coil voltage, which makes it more useful than a frame number alone. DELIXI's group contact page lists its Yueqing industrial park, while the English product site also lists a Shanghai address. Confirm the legal manufacturer, seller and actual production site for the quoted starter.

Before requesting a quote: Send the motor nameplate and required start/stop controls. Ask for the complete CDS2s order code, contactor and overload-relay references, thermal setting range, coil voltage and frequency, housing dimensions and enclosure rating. Obtain the latest wiring diagram and coordination evidence for the specified upstream fuse or breaker.

Official sources: CDS2s electromagnetic starter · CDS2s official catalogue · contact page.

3. People Electrical Appliance Group Co., Ltd.

Short name: PEOPLE
Published location: No. 555 Liule Road, Liushi, Yueqing

PEOPLE publishes both a magnetic-starter category and a separate soft-starter range. The latter includes the RDZR8-SP bypass soft starter. This gives buyers two distinct enquiry routes: a contactor-based starter for direct switching, or a semiconductor starter for controlled acceleration and stopping. Compare the specific product and its wiring requirements; a category containing both types does not make their duties interchangeable. PEOPLE's official contact page places the company on Liule Road in Liushi, Yueqing. Ask which production line and entity will supply the selected family.

Before requesting a quote: Describe the driven load, motor full-load current, starting time and starts per hour. For a magnetic starter, request the contactor and overload pairing. For RDZR8-SP, confirm the bypass arrangement, overload functions, control supply, cooling clearances, fault protection and whether the quotation covers a unit or a wired cabinet.

Official sources: Magnetic starters · RDZR8-SP bypass soft starter · contact page.

4. TENGEN Electric

Short name: TENGEN
Published location: Sulv Industrial Zone, Liushi, Yueqing

TENGEN publishes the TGS51 enclosed direct-on-line (DOL) starter and the TGS3 soft starter. The TGS51 page describes start/stop and forward/reverse control for three-phase squirrel-cage motors, with no-voltage and overload protection; phase-loss protection depends on fitting the specified thermal relay. TGS3 uses semiconductor control for soft starting and stopping, with published protection and environmental data. These families answer different specifications. Confirm the exact TGS51 control configuration or TGS3 model, and read its own catalogue rather than applying the range summary to every size.

Before requesting a quote: Specify DOL, reversing or soft starting, motor current, line voltage and control voltage. Ask TENGEN to confirm the overload element, phase-loss function, contactor interlocks or bypass arrangement, upstream protection and installation conditions. Request the offered model's wiring, dimensions and document package.

Official sources: TGS51 enclosed DOL starter · TGS3 soft starter · contact page.

5. Changan Group

Short name: CHANGAN
Published location: No. 288 Wei 17th Road, Yueqing Economic Development Zone

Changan publishes the CQ1 magnetic starter as a combination of a steel housing, mounting plate, AC contactor, thermal relay and wiring. Its selection table identifies model-dependent overload ranges, rated current and motor-power data. The product description also explains the start/stop control circuit, so the buyer should confirm which operator devices and control wiring are actually supplied. The page cites IEC/EN 60947-4-1. Treat that as a published standard reference and request the document covering the exact CQ1 model and combination for the order.

Before requesting a quote: Provide motor current, operating voltage, coil voltage and frequency. Request the complete CQ1 code, overload adjustment range, matching contactor and thermal relay, reset mode, start/stop buttons, enclosure protection and wiring diagram. Confirm the upstream fuse or breaker and the supported short-circuit coordination for that combination.

Official sources: CQ1 magnetic starter · contact page.

6. Zhejiang Kripal Electric Co., Ltd.

Short name: KRIPAL
Published location: Zhongfang Intelligent Industrial Park, Beibaixiang, Yueqing; also Daqiao Industrial Zone

Kripal publishes UKQ and UKW magnetic-starter families, including the UKW1-22MB. The latter's page describes direct start/stop control of AC motors at 50/60 Hz, with published limits of 550 V and 9 kW, and overload, phase-failure and voltage-loss protection. Those figures describe that product page, not every UKQ or UKW configuration. Kripal also sells contactors and overload relays separately, so make the assembled-starter requirement explicit. Its contact page lists more than one Yueqing address; confirm the site producing and testing the chosen starter.

Before requesting a quote: Send the motor voltage, full-load current, control supply and installation environment. Ask for the complete magnetic-starter code, contactor and overload models, setting range, reset behaviour, push-button arrangement and enclosure rating. Verify the motor-power rating at the actual voltage, dimensions, coordination data and applicable model documents.

Official sources: UKQ magnetic-starter range · UKW1-22MB magnetic starter · contact page.

7. VIOX Electric

Short name: VIOX
Published location: East Innovation Zone, Wengyang Town, Yueqing

VIOX publishes AC contactors and thermal overload relays in its motor-control range. Its JR28 relay page includes setting-current ranges and matching CJX2 contactor references, making it relevant to buyers assembling a contactor-plus-overload motor starter. The verified product pages support this component-platform scope. They do not by themselves establish a complete enclosed starter or a soft-starter model. If you want VIOX to supply an assembled unit, request a separate starter quotation with the complete bill of materials, wiring, enclosure and combination-level documents.

Before requesting a quote: Send the motor current, supply and coil voltages, starting method and target market. Ask for the exact CJX2/JR28 pairing, overload range and trip class, auxiliary contacts and mounting interface. For an assembled quotation, confirm who performs wiring and testing, which protection device is specified and which factory will manufacture the finished starter.

Official sources: AC contactors · JR28 overload relay and matching contactors · contact page.

8. Yueqing Long Road Electric Co., Ltd.

Short name: LONG ROAD
Published location: No. 221 Wei 17 Road, Yueqing Economic Development Zone

Long Road publishes a broader set of starter formats: QCW1 enclosed starters, QCX2 magnetic starters, ADS7 and QCX3 star-delta starters, and the AJR3 motor soft starter. This is useful for a buyer who has not yet fixed the starting method, provided each quotation follows the same motor and load brief. The QCW1 page includes model and AC-3 selection data. For a star-delta enquiry, obtain the full circuit and switching sequence; for AJR3, confirm the bypass and protection arrangement. The existence of several catalogue families does not mean every rating is available in every enclosure.

Before requesting a quote: Specify the driven load, nameplate current, terminal arrangement and starts per hour. For star-delta, request the three contactors, timer, electrical and mechanical interlocks and overload location. For soft starting, request the rated duty, bypass circuit and cooling requirements. Confirm the complete model, wiring diagram and protection coordination.

Official sources: QCW1 enclosed starter · QCX3 star-delta starter · AJR3 soft starter · contact page.

9. Yueqing Winston Electric Co., Ltd.

Short name: WINSTON
Published location: Liufeng Building, Liushi, Yueqing

Winston publishes a motor soft-starter category and a dedicated WSTRD-F3000 built-in-bypass product page. The page describes a wall-mounted metal housing with a control keypad, while its specifications, wiring and dimensions are presented partly as images. Ask for an editable or PDF technical schedule for the offered model rather than extracting a rating from a promotional image or a related product title. The wider catalogue also contains several WSTR and WSTRD variants. Keep their voltage, current, bypass and load-duty data separate during comparison.

Before requesting a quote: Provide motor current, voltage, acceleration time, load type and starts per hour. Request the exact F3000 model, normal or heavy starting duty, overload functions, bypass contactor, control supply and fault outputs. Confirm upstream protection, enclosure ventilation, dimensions, firmware or parameter documentation and the actual manufacturing address.

Official sources: WSTRD-F3000 built-in-bypass soft starter · Motor soft-starter range · contact page.

10. ZIRI Electrical Technology Co., Ltd. (CHZIRI)

Short name: CHZIRI
Published location: Building 2, Phase II, CHINT IoT Sense Industrial Park, Yueqing

CHZIRI publishes ZJR2 soft starters and motor-control panels. The ZJR2 page describes three-phase squirrel-cage motor starting with current-limiting and voltage-ramp options, alongside model tables and a wiring diagram. Its bypass detail matters: the page describes an external bypass arrangement and says an internal bypass is optional for certain smaller models, rather than standard on every unit. Ask for the current manual and written configuration for the quoted model. The site's contact page gives a Yueqing industrial-park address; confirm the production and panel-assembly location when arranging a visit.

Before requesting a quote: State the motor current, line voltage, starting duty and load profile. Confirm the bypass option, input breaker or fuse, motor-protection functions, control inputs, communication and ventilation. If buying a cabinet, request the complete schematic, parts list, panel drawings and factory test scope rather than only the soft-starter unit specification.

Official sources: ZJR2 soft starter · Company and control-panel scope · contact page.

Motor starter quotation checklist

Send every candidate the same motor and load schedule. A low price for a contactor-and-relay kit cannot be compared directly with a wired starter that includes an enclosure, isolator, controls and short-circuit protection.

Include in your enquiry Ask each supplier to confirm
Motor and load Nameplate output, full-load current, voltage, frequency, motor connection, driven equipment, loaded or unloaded start, acceleration time and starts per hour.
Starting method DOL, reversing, star-delta or soft starting. Identify whether the supplier is quoting components, an open assembly, an enclosed starter or a wired control cabinet.
Contactor duty Exact contactor references, operational current and motor-power rating at the actual voltage, utilization category and required electrical operating duty.
Overload protection Thermal or electronic protection, current-setting range, trip class, phase-loss response, reset mode and the protection remaining active during bypass operation.
Control supply Coil and auxiliary-supply voltage, AC/DC and frequency, control transformer if required, local/remote operation, auxiliary contacts and restart behaviour after supply loss.
Reversing and star-delta Mechanical and electrical interlocks, timer, transition sequence, overload-relay position, motor-terminal requirements and the complete approved wiring diagram.
Soft-starter duty Rated current at the stated load duty, start-current limit, acceleration time, starts per hour, ambient derating and whether bypass is internal, external or excluded.
Short-circuit coordination Prospective fault current, exact upstream fuse or breaker, supported combination, coordination type where declared, operating voltage and evidence for that arrangement.
Enclosure and assembly IP rating of the complete supplied assembly, enclosure material, door controls, isolation and locking provisions, cable entries, dimensions, terminals, earthing and heat management.
Installation conditions Ambient temperature, altitude, dust, moisture, corrosion, ventilation, mounting orientation and the effect of the enclosure on continuous and starting duty.
Technical documents Model datasheet, bill of materials, circuit and terminal diagrams, installation manual, settings, test records and the applicable standard or certificate scope for the supplied configuration.
Factory and commercial scope Legal manufacturer and seller, production and assembly addresses, bought-in components, MOQ, sample availability, lead time, warranty and approval process for component substitutions.

Match the documentation to the starting method. IEC 60947-4-1 covers electromechanical contactors and motor starters. IEC 60947-4-2 covers semiconductor motor controllers, starters and soft starters. Ask which standard edition and product configuration the supplier’s documents actually cover. A standard cited on a web page is not a model-specific certificate, and a component certificate does not automatically cover an entire wired cabinet.

Compare duty as well as kW. A catalogue motor-power figure is tied to a voltage and operating condition. A long acceleration, a loaded compressor or frequent restarts can change the required contactor, overload or soft-starter selection. Request the supplier’s selection against your full-load current and duty, including any enclosure or ambient derating.

Check the complete protection combination. An overload relay normally operates the starter’s control circuit; it does not replace the upstream device needed to interrupt a short circuit. Request the exact contactor, overload relay or soft starter, fuse or breaker, voltage and fault level covered by the supplier’s coordination evidence. Our Yueqing MPCB guide covers motor protection circuit breaker suppliers when that device forms part of the specification.

For component sourcing, use the Yueqing contactor guide and thermal overload relay guide. Keep those individual component quotations separate from the assembled-starter price.

What to check during a factory visit

Confirm where the quoted starter is manufactured, wired and tested before booking the visit. A starter supplier may make its own contactors, assemble purchased components or build cabinets around a bought-in soft starter. The route to inspect should follow the actual order.

  • Match the build to the quotation: check contactor, overload, soft-starter, breaker, timer and bypass references against the approved parts list. Record any proposed substitutions.
  • Inspect wiring and assembly: review conductor selection, terminal identification, torque controls, wire retention, protective earthing, separation and access for maintenance.
  • Review the control sequence: ask for documented start, stop, trip, reset and power-restoration checks. For reversing or star-delta equipment, review both electrical and mechanical interlocks.
  • Confirm soft-starter configuration: check the actual bypass hardware, overload settings, current limit, cooling arrangement and parameter records against the agreed duty.
  • Examine test records: review the routine checks and functional tests applicable to the supplied configuration. Ask how the factory selects its test load and records results for the order.
  • Check the enclosure as supplied: compare seals, controls, entries, doors, terminals and ventilation with the drawings and the declared assembly rating.
  • Follow traceability: link component batches, finished-starter labels, settings, test results and packing records to the purchase order.

A visit gives you observations about the production and assembly process. Use the applicable test reports and certification documents to assess the stated ratings and approvals separately.

BottomRace coordinates electrical sourcing and purchasing in Yueqing. Pro: $0 separate service fee; procurement service costs are included in the product quotation. Basic: 5% of product value, with a minimum service fee of $100, for your existing Yueqing suppliers. Compare our Pro and Basic services. For on-site meetings, see our factory visit services. The quotation confirms the scope, inspections, payment terms and any additional costs.

Questions motor starter buyers ask

Should I ask for a DOL starter, a star-delta starter or a soft starter?

Choose the method with the engineer responsible for the motor and driven equipment. DOL applies the line supply directly through the switching arrangement. Star-delta requires a suitable motor and terminal connection, together with the correct switching sequence. A soft starter controls starting and stopping through power semiconductors. Send the motor and load data first; suppliers should explain why their proposed arrangement fits the duty.

Does a motor-starter quotation include the enclosure and breaker?

Only if they are included in the written supply scope. One supplier may quote a contactor and overload relay, another a boxed start/stop unit, and another a complete panel. Ask for an itemized parts list and exclusions covering enclosure, isolation, upstream short-circuit protection, control transformer, operators, cable entries and assembly tests.

What should I confirm about star-delta overload settings?

Ask where the overload relay is installed in the proposed circuit. Its current depends on that position, so a setting copied from a different star-delta diagram can be inappropriate. Have the supplier mark the relay location and required setting on the exact schematic, together with the motor connection, transition timer and interlocks.

Does a built-in-bypass soft starter include every protective device?

No. Bypass describes the running-current path after starting; it does not define the whole protection package. Confirm overload sensing during bypass, the required upstream fuse or breaker, control power, isolation and any external contactors. Request the complete circuit and the selected model’s manual, especially where bypass is an optional configuration.

Can a soft starter provide continuous speed control?

A conventional soft starter is selected for starting and stopping duty. If the application needs continuous variable-speed operation, specify that requirement and evaluate a variable frequency drive with the responsible engineer. Do not purchase a soft starter on the assumption that a ramp-time setting provides normal running-speed control.

Are the ten companies ranked by quality or price?

The numbered order is a research shortlist based on official product and location information. Compare the same motor duty, supply scope, technical evidence and commercial terms across suppliers, then verify the factory and sample. The article does not establish a quality, price, certification or export ranking.

Planning a Yueqing motor starter sourcing trip?

Email your motor nameplate, starting method, control voltage, load duty, quantities and preferred visit dates. We can discuss supplier screening and agreed local support in Yueqing.

contact@bottomrace.com ↗

Enquire about Pro sourcing · Enquire about Basic supplier management.