For a Yueqing capacitor contactor manufacturer shortlist, compare Geyue, HUYU, Hangrong, Yinyue, Youlang, Yadulan, Weidekang, Suheng, Kripal and Hongcheng. Each company publishes a CJ-series or equivalent contactor intended for low-voltage power-capacitor switching, with an official Yueqing-connected source. The important specification is not simply the nominal current: the contactor must be matched to the capacitor voltage, kvar per step, inrush current, switching frequency, control voltage, protection and the early-make resistor circuit.

A capacitor contactor is a switching device for a capacitor bank, not a generic AC-3 motor contactor with a different label. The demanding part is the making operation: an energized capacitor can draw a very high transient current, and repeated switching can stress the main contacts. Many AC-6b designs use early-make contacts and series resistors to pre-charge the capacitor before the main contacts close. The exact circuit, resistor rating and contact sequence must be documented. Our contactor guide, power capacitor guide, smart capacitor guide and reactor guide can help separate the components in a compensation panel.

How this list was selected: Official product, catalogue and contact pages were reviewed on 24 October 2026. This is a research shortlist, not a quality, price, certification, export or “best” ranking. It does not imply that BottomRace has audited every factory or verified every published rating. Confirm the legal entity, production site, exact model, current datasheet and supporting test documents before ordering. A product photograph, inverter name or company-level certificate statement does not prove the performance of the specific contactor you will receive.

Ten Yueqing capacitor contactor manufacturers to compare

Use the published focus to decide which suppliers deserve a technical enquiry. The order is a research sequence, not a performance ranking.

Manufacturer Published location Published capacitor-contactor focus Useful first question
Zhejiang Geyue Electric Technology Co., Ltd. Zhangwan Industrial Zone, Beibaixiang, Yueqing CJ19 capacitor-switching contactors from 25 to 95 Can the supplier reconcile the published model table and confirm the exact kvar rating for each coil voltage?
HUYU Electric Wenzhou Bridge Industrial Park, Beibaixiang, Yueqing CJ19 AC-6b capacitor-switching contactors Is the offered CJ19 rated for the actual capacitor kvar and voltage, rather than only the nominal AC-6b category?
Hangrong Electric (Zhejiang) Co., Ltd. No. 88 Zhandong Road, Dianhou Industrial Zone, Liushi, Yueqing CJ19 switching-capacitor contactors with damping resistors Does the quotation include the main and early-make circuits as a matched assembly, not separate generic contact blocks?
Zhejiang Yinyue Optoelectronics Technology Co., Ltd. No. 177 Wei 5th Road, Yueqing Economic Development Zone CJ16 and CJ19 capacitor-switching contactors Which CJ16/CJ19 frame and resistor arrangement matches the intended capacitor step?
Zhejiang Youlang Electric Co., Ltd. No. 32 Shanggong Road, Shangwu Industrial Zone, Liushi, Yueqing CJ19(16) capacitor contactors from 25 to 95 Does the proposed contactor use a resistor-based early-make circuit, and how is its Auxiliary contact failure detected?
Yadulan Electric (Zhejiang) Co., Ltd. No. 83-87 Zhongshan Avenue, Madao, Liushi, Yueqing CJ19(16) capacitor contactors for stepped compensation Which Yadulan legal entity and plant will manufacture and test the quoted contactor?
Zhejiang Weidekang Electric Co., Ltd. No. 61 Aomen Middle Road, Jiangjiaqiao, Beibaixiang, Yueqing CJ19 switching-capacitor contactor range Can Weidekang provide a current datasheet and test record, not only a product photograph?
Zhejiang Suheng Electric Co., Ltd. No. 58 Nanyang Road Workshop Area, Zhiguang Industrial Zone, Liushi, Yueqing CJ19 switching-capacitor contactors and capacitor-panel components What model-level technical file supports the CJ19 offer beyond the product image?
Zhejiang Kripal Electric Co., Ltd. Zhongfang Intelligent Industrial Park, Beibaixiang, Yueqing UKC1-85C switching-capacitor contactor Does the UKC1 offer include a documented discharge and recharging procedure for the target capacitor bank?
Zhejiang Hongcheng Electric Co., Ltd. Xuezhai Industrial Zone, Liushi, Yueqing CJ19(16) switching-capacitor contactors from 25 to 95 Can Hongcheng provide a current CJ19 catalogue page and a complete early-make resistor circuit?

Manufacturer profiles and sourcing questions

1. Zhejiang Geyue Electric Technology Co., Ltd.

Short name: GEYUE
Published location: Zhangwan Industrial Zone, Beibaixiang, Yueqing

Geyue publishes a CJ19 series AC contactor specifically for switching power capacitors. Its product page covers CJ19-25 through CJ19-95 and describes a direct-acting, double-break construction with early-make contacts and current-limiting resistors. That architecture is important: the auxiliary contacts and resistors are intended to reduce the capacitor inrush before the main contacts close. The page also refers to IEC 60947-4-1 and GB/T 14048.4, but some of the published model and current information is not fully consistent. Use the page as a starting point and ask for one current catalogue sheet, a coil table and a model-specific routine-test record.

Before requesting a quote: State the system voltage, frequency, capacitor kvar per step, number of steps, expected switching frequency, control voltage and whether series reactors are fitted. Ask for the exact CJ19 model, rated operational current, making and breaking capacity, main and auxiliary contact arrangement, resistor value, coil consumption, terminal clearance, fuse or breaker coordination, dimensions and the production site named on the test record.

Official sources: CJ19 AC contactor for switching power capacitors – AC contactor category – company contact details.

2. HUYU Electric

Short name: HUYU
Published location: Wenzhou Bridge Industrial Park, Beibaixiang, Yueqing

HUYU presents CJ19 as a dedicated contactor for switching low-voltage power capacitors. The product page identifies AC-6b utilization category, capacitor-switching duty, inrush suppression and an example rating of up to 50 kvar at 400 V. It also describes the early-make resistor method used to reduce the current surge when a capacitor is energized. These are useful selection details, but the quoted device still needs to be matched to the capacitor bank voltage, step size, reactor arrangement and required electrical life. Ask for the exact model rather than accepting a broad AC-6b description.

Before requesting a quote: Provide the capacitor voltage, kvar per step, number of parallel steps, system frequency, control voltage, upstream fuse or breaker, expected operations per hour and ambient temperature. Request the exact CJ19 model, AC-6b rating at the quoted voltage, making and breaking capacity, early-make contact arrangement, resistor rating, coil data, terminal torque, dimensions, applicable standards and a serial-number-linked routine-test record.

Official sources: CJ19 capacitor-switching contactor – company contact details.

3. Hangrong Electric (Zhejiang) Co., Ltd.

Short name: HANGRONG
Published location: No. 88 Zhandong Road, Dianhou Industrial Zone, Liushi, Yueqing

Hangrong publishes a CJ19 contactor under a product description explicitly aimed at switching capacitors. The page describes early-make contacts, current-limiting resistors and suppression of both inrush current and switching overvoltage. Those functions depend on the complete contact and resistor assembly, so a replacement contact kit should be treated as a controlled spare rather than a generic accessory. The public page is relatively short and should not be used as a complete type-test file. Ask Hangrong to identify the legal supplier and the production site for the exact coil and contact configuration in the quotation.

Before requesting a quote: State the capacitor bank voltage, kvar rating of the largest step, switching frequency, control voltage and required auxiliary contacts. Ask for the exact CJ19 model, AC-6b performance, resistor circuit diagram, contact material, coil operating range, insulation and dielectric data, terminal torque, fuse or breaker coordination, dimensions and a model-specific test record. Request the wiring diagram before approving any spare-part substitution.

Official sources: CJ19 switching-capacitor contactor – company contact details.

4. Zhejiang Yinyue Optoelectronics Technology Co., Ltd.

Short name: YINYUE
Published location: No. 177 Wei 5th Road, Yueqing Economic Development Zone

Yinyue's catalogue includes CJ16 and CJ19 contactors for switching low-voltage power capacitors. Its product page explains the sequence in which the early-make contacts connect resistors to pre-charge the capacitor before the main contacts take over. That explanation is useful for a buyer because it shows why the auxiliary circuit cannot be omitted when the contactor is installed. The company's wider catalogue also covers capacitors, controllers and related reactive-power components. For a project quotation, keep the contactor model, capacitor step and control scheme together so that responsibility for coordination remains clear.

Before requesting a quote: Send the capacitor nameplate, step kvar, system voltage, frequency, reactor percentage if present, control voltage and required number of operations. Request the exact CJ16 or CJ19 model, main and early-make contact ratings, resistor value and duty, coil data, making and breaking capacity, terminal arrangement, dimensions, applicable standards and the test record for the offered batch.

Official sources: CJ16 and CJ19 switching-capacitor contactor – Company profile and capacitor-switching range – company contact details.

5. Zhejiang Youlang Electric Co., Ltd.

Short name: YOULANG
Published location: No. 32 Shanggong Road, Shangwu Industrial Zone, Liushi, Yueqing

Youlang lists CJ19(16)-25, 32, 43, 63, 85 and 95 capacitor contactors in a dedicated switching-capacitor category. The published description refers to AC 50 Hz operation, a 380 V example, inrush suppression and overvoltage suppression. The company also publishes power capacitors, controllers, reactors and compensation assemblies, which can make it a useful single-source candidate for a conventional capacitor panel. That breadth does not remove the need to define the contactors separately from the capacitors and controller. Ask for the exact model schedule and a wiring diagram showing the early-make contacts, resistors, main contacts and coil circuit.

Before requesting a quote: Provide the capacitor bank single-line diagram, voltage, kvar per step, number of steps, reactor details, control voltage and expected switching frequency. Ask for the exact CJ19(16) model, AC-6b rating, early-make resistor arrangement, coil operating range, main and auxiliary contact data, terminal torque, dimensions, applicable standards and a serial-number-linked routine-test record.

Official sources: CJ19(16) capacitor-switching contactor – Capacitor-switching contactor category – company contact details.

6. Yadulan Electric (Zhejiang) Co., Ltd.

Short name: ADULLAN
Published location: No. 83-87 Zhongshan Avenue, Madao, Liushi, Yueqing

Yadulan publishes a CJ19(16) switching-capacitor contactor category covering 25 through 95 A frame sizes, with a 380 V AC example, early-make resistor contacts, inrush suppression and a reference to GB/T 14048.4. The page also mentions DIN-rail mounting for the smaller frames and a different fixing arrangement for larger units. The company says it operates across more than one location, so the quotation should identify the legal manufacturer, assembly plant and testing location. A group-level catalogue is not enough when the buyer needs a consistent spare-part and warranty route.

Before requesting a quote: Confirm the selling entity, manufacturing entity, production address and warranty holder. Provide the capacitor voltage, step kvar, switching frequency, control voltage, upstream protection and mounting method. Ask for the exact CJ19(16) model, AC-6b rating, resistor circuit, main and auxiliary contact arrangement, coil data, terminal torque, dimensions, applicable standards and a test record tied to the offered serial number.

Official sources: CJ19(16) switching-capacitor contactor – Capacitor-switching contactor category – company contact details.

7. Zhejiang Weidekang Electric Co., Ltd.

Short name: WEIDEKANG
Published location: No. 61 Aomen Middle Road, Jiangjiaqiao, Beibaixiang, Yueqing

Weidekang's public product category lists CJ19-25, 32, 43, 63 and 95 switching-capacitor contactors. That gives a buyer a useful starting point for a conventional low-voltage power-factor correction panel. The available detail pages, however, are thin and should not be treated as a complete technical specification. Ask for the current catalogue page, nameplate photograph, coil table, wiring diagram and routine-test record before comparing the offer with another supplier. The enquiry should also establish whether the company manufactures the contactor or sources part of the assembly from another entity.

Before requesting a quote: Provide the system voltage, capacitor kvar per step, number of steps, control voltage, reactor arrangement and required switching life. Request the exact CJ19 model, AC-6b rating, early-make resistor circuit, main and auxiliary contacts, coil consumption, terminal torque, dimensions, standards, legal manufacturer, production site and a serial-number-linked routine-test record.

Official sources: CJ19 switching-capacitor category – Example CJ19 product record – company contact details.

8. Zhejiang Suheng Electric Co., Ltd.

Short name: SUHENG
Published location: No. 58 Nanyang Road Workshop Area, Zhiguang Industrial Zone, Liushi, Yueqing

Suheng publishes a dedicated CJ19 switching-capacitor contactor page and related low-voltage capacitor and control products. The public product material is image-heavy, so this guide does not infer ratings that are not clearly readable in text. That limitation is practical, not a reason to reject the company: it means the buyer should request a current specification sheet, an approved outline drawing and a filled-in model schedule before placing the contactor on a shortlist. The same request should establish whether the early-make contacts, resistors and main contacts are supplied as a matched assembly.

Before requesting a quote: State the capacitor voltage, kvar per step, frequency, control voltage, expected operations and any series reactor. Request the exact CJ19 model, AC-6b data, early-make circuit diagram, resistor rating, contact arrangement, coil operating range, terminal torque, dimensions, applicable standards, production site and a serial-number-linked routine-test record.

Official sources: CJ19 switching-capacitor contactor – Switching-capacitor contactor category – company contact details.

9. Zhejiang Kripal Electric Co., Ltd.

Short name: KRIPAL
Published location: Zhongfang Intelligent Industrial Park, Beibaixiang, Yueqing

Kripal publishes the UKC1-85C as a switching-capacitor contactor. Its product page discusses capacitor-bank arrangements, discharge before recharging, fuse selection and the use of impedance wire. Those points belong in the panel design, not only in the contactor purchase order. The page contains a malformed standards reference and broader company-level certification statements, so do not treat those as proof that every UKC1 variant carries a particular approval. Ask for the exact model, the revised datasheet and the test evidence tied to the offered product. Confirm the relationship between the contactor and the resistor or damping circuit shown in the proposed wiring diagram.

Before requesting a quote: Provide the capacitor bank voltage, kvar per step, discharge circuit, switching frequency, control voltage, upstream fuse or breaker and reactor details. Ask for the exact UKC1 model, AC-6b rating, main and early-make contact arrangement, resistor data, coil range, terminal torque, applicable standards, certificate scope, production site and a serial-number-linked routine-test record. Request a corrected datasheet where the published standard reference is unclear.

Official sources: UKC1-85C switching-capacitor contactor – Company profile – company contact details.

10. Zhejiang Hongcheng Electric Co., Ltd.

Short name: HONGCHENG
Published location: Xuezhai Industrial Zone, Liushi, Yueqing

Hongcheng's public product metadata lists CJ19(16)-25 through 95 switching-capacitor contactors, with AC 50 Hz operation, a 380 V example, inrush suppression and a GB/T 14048.4 reference. The public page exposes limited technical detail, so it is best used as a sourcing lead and an invitation to request the current catalogue. Ask for the main and early-make contact arrangement, resistor value, coil table, terminal data and type or routine-test evidence. Also confirm the legal manufacturer and the plant that will produce the exact model; a company product index alone does not establish the production site for a particular batch.

Before requesting a quote: State the capacitor voltage, kvar per step, frequency, control voltage, number of steps, expected operations and series reactor details. Request the exact CJ19(16) model, AC-6b performance, early-make resistor circuit, main and auxiliary contacts, coil operating range, terminal torque, dimensions, applicable standards, production site and a serial-number-linked routine-test record.

Official sources: CJ19(16) switching-capacitor product record – company contact details.

Capacitor contactor quotation and design checklist

A capacitor-contactor quotation can look complete while leaving the capacitor rating, early-make circuit, protection and operating duty unstated. Give every supplier the same panel data and ask for a model-specific selection, not a price for a generic AC-6b contactor.

Include in your enquiry Ask each supplier to confirm
Capacitor step System voltage and frequency, capacitor rated voltage, kvar per step, number of parallel steps, connection arrangement and whether the capacitor is delta or star connected.
Switching duty AC-6b utilization category, making and breaking current, expected inrush, operations per hour, required electrical life and the exact test condition behind the published rating.
Early-make circuit Main and early-make contact arrangement, series resistor value and power rating, pre-charge time, contact sequence and what happens if a resistor or auxiliary contact fails.
Coil and control Rated control voltage, operating range, coil consumption, pick-up and drop-out behaviour, control-circuit protection and compatibility with the controller or switching logic.
Protection and coordination Upstream fuse or breaker type, gG or semiconductor fuse where used, short-circuit coordination, capacitor discharge path, residual-voltage limit and isolation procedure.
Reactors and harmonics Series reactor percentage and position, capacitor terminal voltage, harmonic spectrum, resonance risk, temperature rise and whether the selected contactor rating already accounts for the reactor current.
Thermal and mechanical Rated ambient, altitude, IP or enclosure condition, mounting orientation, terminal size, cable and busbar entry, tightening torque, creepage, clearance and expected heat loss.
Switching frequency Expected operations per day, duty cycle, step rotation, minimum off time, discharge time and whether the contactor is intended for a rapidly switched filter or a conventional capacitor bank.
Testing and standards Applicable IEC or GB standard, type tests, routine tests, dielectric and insulation checks, contact resistance, pick-up and drop-out test, temperature-rise evidence and serial-number traceability.
Commercial identity Legal manufacturer, seller, production site, country of origin, warranty holder, spare-part route, drawing revision and the technical contact responsible for commissioning.

Do not substitute an ordinary AC-3 contactor. A motor contactor may have the same mounting width or a similar-looking coil, but its contact system and making capacity are selected for motor duty, not repeated capacitor switching. If a supplier proposes a standard contactor, ask for the capacitor-switching calculation, the external pre-charge arrangement and the manufacturer’s written approval for that use. A catalogue current alone does not prove AC-6b capability.

Check the complete early-make assembly. The resistor contacts, resistors, main contacts and coil are a coordinated mechanism. A replacement contactor with a different resistor value or contact timing can change the inrush and the voltage stress on the capacitor. Keep the approved wiring diagram, bill of materials and replacement-part list with the panel record. If a resistor is damaged, do not replace it with an arbitrary resistor taken from another model.

Keep the panel responsibility visible. The contactor supplier may not design the capacitor bank, select the reactor, set the controller or verify the discharge time. The panel builder or system designer must confirm the step kvar, protection, conductor size, temperature rise and switching sequence. Compare quotations by the functions included and the documents supplied, not by the contactor price alone.

What to check during a capacitor contactor factory visit

Arrange the factory visit after the supplier has identified the exact model, coil voltage and production site. Ask which operations are performed in-house: contact stamping, coil winding, resistor assembly, moulding, calibration, dielectric testing, functional testing and final packing.

  • Inspect the contact assembly: compare the main contacts, early-make contacts, resistor mounting, arc covers and terminal barriers with the approved drawing. Look for loose resistor leads, uneven contact alignment and damaged insulation.
  • Verify the switching sequence: ask to see a functional demonstration or test fixture that shows the early-make circuit operating before the main contacts. Confirm the sequence for both energization and de-energization.
  • Review the coil and magnetic system: check coil voltage marking, insulation, terminal spacing, shading ring or electronic control, pick-up and drop-out behaviour and audible noise at the intended control voltage.
  • Check the resistor circuit: confirm the resistor type, resistance, power rating, mounting method and thermal clearance. Ask how the design behaves if the resistor opens or the auxiliary contact sticks.
  • Watch the electrical tests: request contact resistance, insulation resistance, dielectric withstand, coil pick-up and drop-out, functional operation and any applicable temperature-rise or endurance test. Record instrument calibration and serial numbers.
  • Trace the materials and parts: ask for incoming inspection records for contacts, coils, resistors, springs, mouldings and terminals. Confirm that the parts used in the sample match the parts released for production.
  • Inspect the production line: look at assembly fixtures, screw torque control, contact alignment, resistor soldering or clamping, cleaning, marking and final inspection. Note whether critical operations are performed at the named plant.
  • Review the drawings: obtain the outline drawing, wiring diagram, terminal schedule, coil table, nameplate layout and replacement-part list. Check that the drawing revision matches the quotation.
  • Confirm the entity and site: verify the legal manufacturer, seller and production address for the contactor, coil, resistor assembly and moulded parts. If production is shared across sites, state which site will make the offered batch.
  • Keep the scope of a visit clear: a factory visit provides observations and a document trail; it does not replace type testing, a protection study or an independent electrical inspection.

BottomRace coordinates electrical sourcing and purchasing in Yueqing. Pro: $0 separate service fee; procurement service costs are included in the product quotation. Basic: 5% of product value, with a minimum service fee of $100, for your existing Yueqing suppliers. Compare our Pro and Basic services. For on-site meetings, see our factory visit services. The quotation confirms the scope, inspections, payment terms and any additional costs.

Questions capacitor contactor buyers ask

Is a capacitor contactor the same as a normal AC contactor?

No. A capacitor contactor is selected for capacitor-switching duty, commonly described as AC-6b, and may include early-make contacts and series resistors to control inrush. A standard motor contactor is normally selected for AC-3 or another motor duty. Similar dimensions or a similar coil voltage do not make the devices interchangeable.

Why are early-make contacts and resistors used?

When a capacitor is switched on, the initial current can be much higher than the steady capacitor current. The early-make contacts connect resistors briefly to limit the surge, then the main contacts close to carry the operating current. The resistor value, contact timing and contact material must be matched to the capacitor step and the intended switching frequency.

Can I use a capacitor contactor for a detuned bank with reactors?

Often a suitable contactor can be used, but the rating must be checked against the actual capacitor terminal voltage, reactor current and harmonic duty. Do not assume the same model selected for a conventional 400 V bank is correct for a detuned bank. Give the supplier the single-line diagram, capacitor voltage, reactor percentage, step kvar and measured harmonic spectrum.

How often can a capacitor contactor switch?

The permissible switching frequency depends on the contactor design, capacitor discharge time, controller strategy, ambient temperature and required electrical life. Ask for a model-specific operations-per-hour or operations-per-day limit and the corresponding test condition. A controller that commands frequent switching can wear out a contactor that is electrically adequate for steady-state current.

What fuse or breaker should protect the capacitor circuit?

The protective device must be coordinated with the capacitor current, cable, contactor, reactor and expected inrush. Kripal’s public page mentions a gG fuse selected at a multiple of circuit current, but a published example is not a universal rule. Ask the panel designer to calculate the rating and verify the manufacturer’s coordination table for the exact contactor and capacitor arrangement.

What should a quotation include?

Ask for the exact model, coil voltage, main and auxiliary contact arrangement, AC-6b rating, early-make resistor data, outline drawing, wiring diagram, terminal torque, applicable standards, production site, warranty holder and a serial-number-linked routine-test record. For a complete panel, add the capacitor, reactor, fuse or breaker, controller, busbar and enclosure schedules.

Are these companies ranked by quality, price or export volume?

No. This is a research shortlist based on published product and location information. It is not a quality, price, certification, export or “best” ranking. The article does not establish that every company manufactures every capacitor-contactor type at the stated address, and BottomRace has not audited every factory for this list.

Planning a Yueqing capacitor-contactor sourcing trip?

Email the system voltage, capacitor kvar per step, switching frequency, control voltage and visit dates. We can discuss supplier screening and agreed local support in Yueqing.

contact@bottomrace.com